Digital Noise Reduction-DNR-18

DNR-18 Digital Noise Reduction Device is a professional acoustic water-leak detector designed to make hidden pipeline leak sounds easier to identify in noisy environments. Its patented digital filtering system reduces interference from traffic, footsteps, voices and other sudden background sounds while adjustable filters help isolate useful leak frequencies.

The device offers three noise-reduction levels, a large LCD, 250-point measurement memory, USB data transfer, approximately 24-hour battery operation, an IP52-equivalent main unit and IP67-equivalent pickup sensor. Nassguard supplies DNR-18 across Qatar and Doha, including Al Rayyan, Al Wakrah, Al Khor, Al Shamal, Umm Salal, Al Daayen and Al Shahaniya.

More Details

Digital Noise Reduction Device water leakage often creates a continuous sound as pressurised water escapes through a damaged pipe, joint or fitting. However, finding that sound in a busy street, industrial area or commercial property can be difficult. Passing vehicles, footsteps, machinery, conversations, animals and electrical equipment can all interfere with leak detection.

The Digital Noise Reduction Device DNR-18 is a professional acoustic water leak detector developed to make leak sounds easier to identify in noisy environments. Unlike a basic listening device, the DNR-18 digitally processes the sound collected by its pickup sensor and reduces unwanted intermittent background noise.

FUJI TECOM equips the DNR-18 with a patented digital noise-reduction system, adjustable band-pass filters, a 50/60 Hz notch filter, a large LCD display, sound-level recording and USB data transfer. Its internal memory can store minimum leak-noise values from up to 250 survey locations.

Nassguard supplies the Digital Noise Reduction Device DNR-18 across Qatar and Doha, including Doha (Ad Dawhah), Al Rayyan, Al Wakrah, Al Khor, Al Shamal, Umm Salal, Al Daayen and Al Shahaniya for water-network contractors, utility maintenance teams, leak-detection specialists, facility managers and industrial maintenance companies.

What is a Digital Noise Reduction Device?

A Digital Noise Reduction Device for water leakage is an acoustic instrument that listens for vibration or sound generated when pressurised water escapes from a pipeline. Traditional listening equipment can amplify leak sounds, but it can also amplify surrounding noise. This creates difficulties when technicians work beside roads, construction sites, factories or populated areas. The DNR-18 addresses this problem through digital signal processing.

FUJI TECOM states that the device uses an advanced digital CPU to reduce intermittent noises including passing vehicles, people talking, footsteps and animal sounds. Traditional filters remain useful for continuous background noise such as air-conditioning hum, idling motors and wind. Therefore, DNR-18 combines digital noise reduction with conventional filtering to provide better control over the sound that reaches the operator. The system also converts measured leak-noise levels into visual information on its LCD. This means the operator does not have to depend completely on hearing alone.

Key Features of DNR-18 Digital Noise Reduction Device

  • Digital Noise Reduction: Reduces sudden interference such as passing traffic, footsteps and animal sounds.
  • Three Noise Reduction Levels: Provides Level 1, Level 2 and Level 3, plus an OFF setting.
  • Digital Signal Processing: Uses electronic processing to make leak noise easier to distinguish.
  • Adjustable Band-Pass Filters: Allows operators to select different frequency ranges according to the leak sound.
  • 50/60 Hz Notch Filter: Helps reduce electrical hum from transformers and power systems.
  • Large LCD Display: Shows sound level, filter settings and recorded information clearly.
  • Graphical Leak-Level Display: Helps users compare sound levels visually.
  • 250-Point Memory: Stores minimum noise-level measurements from as many as 250 locations.
  • USB Data Transfer: Allows stored information to be transferred to a computer.
  • Long Battery Operation: Provides approximately 24 hours of continuous use under manufacturer test conditions.
  • IP52-Equivalent Main Unit: Provides useful protection for field survey work.
  • IP67-Equivalent Pickup Sensor: Suitable for demanding water-network environments.

Uses of Digital Noise Reduction Device DNR-18

  1. Water Leak Pinpointing- The DNR-18 helps technicians narrow down the location of an underground water leak before excavation begins.
  2. Water Distribution Network Surveys- Utility companies can use the Noise Reduction Equipment when checking valves, pipelines and other accessible network points for possible leakage.
  3. Roadside Leak Detection- Traffic noise often makes conventional acoustic investigation difficult. DNR-18 helps suppress intermittent vehicle noise so operators can focus more effectively on leak sounds.
  4. Pipeline Maintenance- Maintenance teams can use the Pipeline Noise Reduction Device while checking pressurised pipelines for suspected leakage.
  5. Ground-Level Leak Detection- With the appropriate pickup arrangement, operators can compare acoustic levels at several locations directly above the pipeline to identify where the signal becomes strongest.
  6. Valve and Fitting Surveys- An optional pickup sensor can assist with acoustic surveys at valves and other accessible pipeline fittings.
  7. Industrial Water Networks-The Acoustic Noise Filter function can help technicians work around industrial facilities where mechanical and environmental sounds may interfere with water-leak investigation.
  8. Residential Water-Leak Investigation- FUJI TECOM lists DNR-18 for both public-road and residential-property leak investigation.
  9. Leak Survey Documentation- Stored sound-level measurements can be transferred by USB for checking, record keeping and inclusion in survey reports.
  10. Preventive Pipeline Maintenance- Regular acoustic surveys can help maintenance departments identify suspected leaks before they develop into larger water losses.

Applications Across Qatar and Doha

The Digital Noise Reduction Device can support water-network maintenance throughout Qatar, particularly in locations where surrounding environmental noise makes conventional acoustic leak detection difficult.

  • Doha (Ad Dawhah)- Busy roads, construction activities and commercial areas make Doha a suitable environment for digital noise-reduction leak detection. DNR-18 can support water-main surveys, facility maintenance and underground pipeline investigation.
  • Al Rayyan- Utility contractors and facility-management companies in Al Rayyan can use DNR-18 for residential, institutional and commercial water-network surveys.
  • Al Wakrah- In Al Wakrah, the device can support underground water-pipeline maintenance, leak pinpointing and infrastructure inspections.
  • Al Khor- Industrial facilities and utility networks around Al Khor can use the Leak Detection Noise Filter to investigate suspected pressurised water-pipeline leaks.
  • Al Shamal- Maintenance teams working across Al Shamal can use DNR-18 for municipal and infrastructure water-network inspections.
  • Umm Salal- In Umm Salal, contractors can compare leak-noise levels before selecting an excavation point for repair.
  • Al Daayen- New developments in Al Daayen require reliable underground utility maintenance, making acoustic leak-detection equipment useful for ongoing network management.
  • Al Shahaniya- DNR-18 can support municipal, commercial and infrastructure water-leak investigations throughout Al Shahaniya.

Therefore, Nassguard supplies the Digital Noise Reduction Device DNR-18 throughout Qatar, covering central Doha as well as surrounding municipalities and industrial regions.

Technical Specifications

Specification DNR-18 Details
Product Name Digital Noise Reduction Water Leak Detector
Model DNR-18
Product Type Acoustic Water Leak Detection Device
Total Sensitivity 900 V/g at 400 Hz
High-Pass Filter Thru, 100, 200, 400 Hz
Low-Pass Filter 400, 600, 800, 1200, 2200 Hz
Notch Filter 50 Hz / 60 Hz / OFF
Noise Reduction System OFF / Level 1 / Level 2 / Level 3
Stored Information Minimum Level, Data No., Date/Time, Flag Information
Memory Capacity 250 Files / Locations
External Interface USB
Main Unit Power 4 × LR14 / C-Size Alkaline Batteries
Operating Time Approx. 24 Hours
Operating Temperature -20°C to +55°C
Main Unit Protection IP52 Equivalent
Main Unit Dimensions 163 × 76.5 × 145 mm
Main Unit Weight Approx. 780 g, Excluding Batteries
Pickup Type Piezoelectric
Pickup Power Supply DC 3.3 V
Pickup Protection IP67 Equivalent
Pickup Dimensions Approx. Ø78 × 50 mm
Pickup Weight Approx. 580 g
Headphones Stereo, Closed Type
Headphone Impedance 60 Ω
Headphone Connector Ø6.3 mm

These figures come from FUJI TECOM’s current DNR-18 product specifications and manufacturer catalogue.

How Does DNR-18 Work?

DNR-18 operates using acoustic leak detection. When pressurised water escapes through a crack, damaged connection or hole in a pipeline, the escaping water creates vibration and noise. That vibration can travel through the pipe, fittings and surrounding ground. The operator places the pickup sensor at a suitable location. Depending on the survey method, this may involve checking the ground above the pipeline or accessible pipeline fittings.

The sensor converts the vibration into an electrical signal. Next, the DNR-18 amplifier processes that signal. The operator can select frequency filters according to the type of sound being investigated. The digital noise-reduction system then helps suppress unwanted intermittent disturbances. Finally, the operator listens through headphones and observes the LCD sound-level display. By comparing measurements at several positions, the technician can identify the area producing the strongest consistent leak signal.

Certifications, Standards and Compliance

Why Choose DNR-18 Digital Noise Reduction Device from Nassguard?

  • Patented Digital Noise Reduction: Helps suppress intermittent environmental noise.
  • Three NR Levels: Allows adjustment according to site conditions.
  • Wide Filter Selection: Helps operators isolate useful leak frequencies.
  • 50/60 Hz Notch Filter: Reduces mains-frequency electrical interference.
  • Large LCD: Makes acoustic measurements easier to compare.
  • Leak-Level Graphing: Supports visual leak-location assessment.
  • 250-Point Storage: Keeps multiple field measurements in memory.
  • USB Connectivity: Makes survey-data transfer easier.
  • 24-Hour Battery Operation: Supports extended field surveys.
  • IP52-Equivalent Main Unit: Designed for outdoor field investigation.
  • IP67-Equivalent Pickup: Provides enhanced protection around water-network environments.
  • Qatar-Wide Supply: Nassguard supplies DNR-18 across Doha, Al Rayyan, Al Wakrah, Al Khor, Al Shamal, Umm Salal, Al Daayen and Al Shahaniya.

Frequently Asked Questions

1. What is the DNR-18 Digital Noise Reduction Device used for?

DNR-18 is used to listen for and help pinpoint hidden leaks in pressurised water pipelines while reducing environmental noise that can interfere with acoustic surveys.

2. What type of noise can DNR-18 reduce?

Its digital filter is designed to reduce intermittent sounds such as passing vehicles, footsteps, voices and animal sounds.

3. How many noise-reduction levels does DNR-18 have?

The device provides OFF, Level 1, Level 2 and Level 3 settings.

4. Can DNR-18 store leak survey results?

Yes. The internal memory stores minimum sound-level information for up to 250 measurement locations.

5. Can the recorded information be transferred to a computer?

Yes. DNR-18 includes a USB interface for transferring stored measurements to a computer.

6. Is DNR-18 suitable for outdoor leak surveys?

Yes. The manufacturer lists the main unit as IP52 equivalent and the pickup sensor as IP67 equivalent, making the system suitable for professional field surveys when used according to its instructions.

7. Where can I buy DNR-18 in Qatar?

Nassguard supplies the Digital Noise Reduction Device DNR-18 across Qatar and Doha, including Al Rayyan, Al Wakrah, Al Khor, Al Shamal, Umm Salal, Al Daayen and Al Shahaniya.

Conclusion

The Digital Noise Reduction Device DNR-18 gives water-leak detection teams a practical way to investigate pipelines in locations where environmental noise makes ordinary listening difficult. Its main advantage is the patented digital noise-reduction system, which can suppress intermittent disturbances such as passing vehicles, footsteps and animal sounds. Operators can select from three noise-reduction levels depending on field conditions. At the same time, adjustable band-pass filters help isolate useful leak frequencies, while the 50/60 Hz notch filter can reduce electrical hum. DNR-18 also turns acoustic investigation into a more measurable process. The large LCD displays sound levels and recorded information, while internal memory stores data from up to 250 survey locations. Technicians can compare these measurements to identify where the leak signal becomes strongest. Afterwards, USB connectivity allows data transfer to a computer for documentation and reporting.

The equipment is suitable for underground water-main surveys, roadside leak detection, residential networks, industrial pipelines, facility-management systems and preventive water-loss investigations. Its main unit carries an IP52-equivalent rating, while the piezoelectric pickup sensor is listed as IP67 equivalent. The manufacturer specifies an operating temperature range from -20°C to +55°C, making the instrument suitable for demanding field environments. For utility contractors, water-loss teams, civil companies and maintenance specialists looking for Noise Reduction Equipment, an Acoustic Noise Filter, Digital Noise Filter or Leak Detection Noise Filter, DNR-18 offers a professional solution for acoustic leak investigation.

Nassguard supplies the Digital Noise Reduction Device DNR-18 throughout Qatar and Doha, including Doha (Ad Dawhah), Al Rayyan, Al Wakrah, Al Khor, Al Shamal, Umm Salal, Al Daayen and Al Shahaniya.

Datasheet/Catalogue

Reviews

Be the first to review “Digital Noise Reduction-DNR-18”

Your email address will not be published. Required fields are marked *

Please contact us if you have any questions or want to place a bulk order.

0
Your Cart is empty